Certified Datacenter Specialist (CDCS)
Introduction
With few exceptions, enterprises today rely on IT for the delivery of business-critical services - often directly to the end consumer. It is therefore vital that the mission critical datacenter is designed, maintained and operated with hi-availability and efficiency in mind. Fact is however that most datacenters do not meet the full availability, capacity, safety or efficiency requirements often demanded.
CDCS® will further increase attendees to a level being a compatible sparring partner with suppliers and they will be able to verify offers provided by vendors for correctness, effectiveness and efficiency. CDCS® is a must have certication for professional datacenter managers a…
Es wurden noch keine FAQ hinterlegt. Falls Sie Fragen haben oder Unterstützung benötigen, kontaktieren Sie unseren Kundenservice. Wir helfen gerne weiter!
Introduction
With few exceptions, enterprises today rely on IT for the
delivery of business-critical services - often directly to the end
consumer. It is therefore vital that the mission critical
datacenter is designed, maintained and operated with
hi-availability and efficiency in mind. Fact is however that most
datacenters do not meet the full availability, capacity, safety or
efficiency requirements often demanded.
CDCS® will further increase attendees to a level being a compatible
sparring partner with suppliers and they will be able to verify
offers provided by vendors for correctness, effectiveness and
efficiency. CDCS® is a must have certication for professional
datacenter managers and personnel. CDCS® is a pre-requisite for
individuals wishing to achieve the CDCE® status.
Target Audience
The primary audience for this course is an IT, facilities or Datacenter Operations professional working in and around the datacenter and having the responsibility to achieve and improve hi-availability and manageability of the Datacenter.
Foreknowledge
Certified Datacenter Professional (CDCP)
Goal
- Understand the design life cycle of datacenters and the stages involved
- Discuss in great level of detail requirements with vendors, suppliers and contractors to ensure they meet the customers requirement
- Verify on the technical level design plans, quotes and offers proposed by vendors/contractors
- Understand Tier-levels for both the data centre design/setup as well as maintenance tier levels
- Understand the various building considerations such as bullet proofing, mitigation of seismic activity, fire ratings and thermal stability
- Understand how to build up a raised floor meeting requirements to avoid misalignment, level differences and leakage
- Understand how to read a Single Line Electrical Diagram being able to identify the most common design issues made
- Choose the correct UPS and parallel conguration, learn how to avoid classic mistakes when installing systems in parallel
- Understand how to calculate battery banks enabling you to double check offered congurations to ensure it meets the customers requirements
- Understand what distance to keep to avoid EMF issues for human safety and equipment disturbances
- Understand the fundamental cooling setup, CFM, Delta-T and other important factors
- Understand contamination factors and limitations
- Understand full details of re suppression options, how to calculate gas content and verify installations
- Understand how to measure datacenter energy effciency and how to improve it
Topics
-
- Datacenter Design / Life Cycle Overview
- Overview of the phases of a data centre life cycle
- Planning, re-alignment and continuous improvement
- Tier Levels
- History of tier level definitions
- Tier level definitions, categories and measure points
- Redundancy options
- Tiered Infrastructure Maintenance Standards (TIMS)
- Building Considerations & Standards
- Floor loading requirements
- Fire rating for walls and glass
- Blast protection
- Bullet proofing
- Forced entry protection
- Advanced Raised Floor & Suspended Ceiling
- Raised floor installation guidelines to ensure contractors install a proper closed and levelled raised access floor
- Choosing the right tiles and their locations
- Seismic mitigating floor constructions
- Choosing the correct suspended ceiling
- Advanced Power
- Power infrastructure layout
-
- Formulas which you should know for the datacenter
- Single Line Electrical diagrams; how to read to ensure key components are present for protection
- Over current protection devices (MCB/MCCB/VCB/ACB/Fuses) definitions and what to use where
- Earth Leakage devices (RCB/RCD/ELCB/GFCI/ALCI/RCBO) definitions and what to use where
- Lightning strikes and surge protection devices (TVSS/SPD), how they operate, where to use and how to install
- Power cabling and cable run considerations
- PDU/DB setup and minimum requirements
-
- Generators
- Component make up
- Choosing the required device
- Calculate required fuel storage tank capacity
- Paralleling of gen-sets
- Regulatory requirements
- UPS Systems
- Required specifications for UPS systems
- How to read data sheets and select the correct UPS
- Requirements for parallel congurations and avoid pitfalls such as single point of failures
- How parallel installation should be done, classic mistakes made by installers and how to avoid these
- Harmonic Filters
- Type of filters available and which one to select depending on the application
- Battery Banks
- Designing battery banks, how to calculate, and double check the battery bank to be installed
- Battery charging pitfalls and ensuring the right charger is being installed and used
- Using parallel battery banks; how to properly install them, limitations and risk when using batteries in parallel
- How to test batteries correctly and make decisions on cell/block or string replacement
- Battery casing choices; ABS, V0, V1, V2
- Alternative energy storage; ywheel, re-useable cell etc
- Power infrastructure layout
- Advanced Electro Magnetic Fields
- Differences between single, three phase and bus-bar EMF
- Options available to measure EMF and how to interpret the results from single axe and composite measurements
- Guidance on safe distance for equipment and humans
- Datacenter Design / Life Cycle Overview
- Calculation of EMF attenuation factor for shielding material
permeability and saturation factors
- Advanced Cooling
- Environmental class denitions and thermal specications
- Equipment airflow and Delta-T denitions and limits
- Planning for floor, rack and cooling equipment
- CFM requirement calculations and conversions
- Air-conditioner specications and how to select the correct air-conditioner with the required capacity and flow
- Techniques for optimization of air flow
- Redundancy guidelines for air-conditioners avoiding classic misconceptions
- Liquid cooling guidelines for data centres
- Advanced Fire Protection
- Fire triangle and elements to stop a fire
- Detection systems in detail (VESDA, VIEW, Smoke sensors)
- Considerations for installation of sensors
- Difference in water based systems i.e. dry-pipe, pre-action and why most of them don′t work and how to detect this
- Details on Inert, Halocarbon, fluorinated systems and how to select the correct gas for your data centre
- How to calculate the gas content ensuring the appropriate level is installed to suppress the fire
- Other requirements for gas systems (release times, hold times, pipe install requirements and other important factors
- Requirements for the fire panel
- Installation verication, what to check and how
- New fire suppression techniques which prevents fires from igniting
- Cable Management
- In rack power and network cabling
- Labelling based on TIA-606
- Environmental Specications
- Acoustic noise regulations, specications, effects and limits
- Data centre contaminations and classications
- Measurements, standards and limits
- Preventive measures and avoidance
- Electro Static Discharge (ESD)
- Datacenter Efficiency
- Power efficiency indicators
- How to measure it and what are acceptable numbers compared to the general industry
- How to achieve power savings in the data centre; various techniques to save energy in all parts of the datacenter i.e. application/system level, cooling, power distribution
- Advanced Cooling
Es wurden noch keine FAQ hinterlegt. Falls Sie Fragen haben oder Unterstützung benötigen, kontaktieren Sie unseren Kundenservice. Wir helfen gerne weiter!
